Stroke Symptoms - Activation of Stroke Response

If a patient enters Emergency Department with symptoms of stroke with onset more than three hours, or even three or four days prior to ED visit, do the CT and labs need to be performed within the 45 minute timeframe required in the standard?

Any examples are for illustrative purposes only.

Patients who present to the Emergency Department with new onset of stroke symptoms would need to be evaluated to determine the time of symptoms onset or last known well. The organization would define in their Clinical Practice Guidelines using evidence based practices, would identify a window for consideration for treatment with tissue plasminogen activator(t-PA). Patients who present within the treatment window, would activate the Acute Stroke Activation Response and would be required to perform the diagnostic brain image (head CT) completed (and results reported to or reviewed by a member of the stroke team) within 45 minutes of it being ordered, when clinically indicated (in acute hemorrhagic or ischemic stroke resuscitation candidates)."

Acute resuscitation or treatment may include evaluation for use of MERCI retrieval device for ischemic stroke, reversible of coagulopathy, surgical intervention, or blood pressure management as evidenced-based approved modalities for hemorrhagic stroke. If in the judgment of the treating physician(s) it is determined that an expedited CT is not required, the rationale for this decision should be documented in the medical record, and the team should proceed accordingly. However, in the event of unknown time of symptom onset, the recommendation would be to treat the patient as a candidate for IV thrombolytic therapy until such time of symptom onset is known.
Manual: Advanced DSC - Primary Stroke Center
Chapter: Performance Measurement DSPM
First published date: April 11, 2016 This Standards FAQ was first published on this date.
This page was last updated on October 29, 2021
Was this response helpful?

If no, please comment on how we could improve this response.

If you have additional standards-related questions regarding this topic, please use the Standards Online Submission Form

Get Extra Help with Books and E-books

Browse our gallery of books and e-books to find trusted prep and readiness resources, practical checklists and toolkits, and resources on specialized health care topics.

Stay Informed with Online Education

Online education is the most convenient and cost-effective way to educate your staff and minimize expenses without the need to leave your organization.

Reach Your Safety Goals with eProducts

Assessing and sustaining compliance with accreditation standards or CMS CoPs can be a challenge, but it doesn’t have to be. Rely on our proven software solutions developed by our team of industry experts.

Can't Find What You're Looking For?

If you do not find an answer to your question, please contact the Standards Interpretation Group (SIG).

Note: To provide adequate support to those organizations that are either accredited/certified or seeking accreditation/certification, we will only answer those questions submitted by those organizations seeking accreditation/certification or currently accredited/certified by the Joint Commission. The Joint Commission no longer answers questions submitted by students or vendors. Thank you for your understanding.